ETS-Lindgren 2181 Turntable User Manual
Page 24

24
| Assembly
and
Installation
•
Small flat blade screwdriver
•
Phillips #2 bit driver
• Adhesive
tape
I
NSTALLATION
S
TEPS
1. Choose a location for the IR infrared sensor that is away from traffic.
2. Using a 1-in hole saw, cut an opening in the floor for the IR sensor.
3. Connect the V+, GND, and SIG wires to the IR sensor as shown in the
diagram, and feed the cable through the hole.
4. Use the 1/16-in drill bit and four flathead mounting screws to mount the
IR sensor collar.
5. Connect the V+, GND, and SIG wires from the IR sensor to the
IR-100 control unit as shown in the diagram.
6. Using adhesive tape, attach the IR flasher LED directly over the IR input
on the motor control box.
7. Connect the IR flasher to port 1 on the IR-100 control unit.
8. Plug the 9-12VDC power supply into the power connector on the
IR-100 control unit, and then plug the power supply into a 120 VAC
outlet.