0 electrical specifications, Model 7405, Preamplifier – ETS-Lindgren 7405 E & H Near Field Probe Set User Manual
Page 13
Advertising

www.ets-lindgren.com
Electrical Specifications
13
3.0 Electrical Specifications
Model 7405
Primary
Sensor Type
E/H or H/E
Rejection
Upper
Resonant
Frequency
901
6-cm loop
H-Field
41 dB
790 MHz
902
3-cm loop
H-Field
29 dB
1.5 GHz
903
1-cm loop
H-Field
11 dB
2.3 GHz
904
3.6-cm ball
E-Field
30 dB
>1 GHz
905
6-mm stub tip
E-Field
30 dB
>3 GHz
Preamplifier
Absolute Maximum Ratings:
Input Voltage (DC): 12 VDC
Input Voltage (AC): +20 dBm
Bandwidth:
100 kHz
–3 GHz
Noise Figure
(Ref. 50 ohms):
3.5 dB (typical)
Saturated Output Power
(at F = 100 MHz):
+12.0 dBm
1 dB Gain Compression
(at F = 100 MHz):
+10.0 dBm
Third Order Intermodulation
Intercept:
+23 dBm
Advertising