General Hydroponics WaterFarm Upgrade User Manual

Circulating upgrade kit

Advertising
background image

13/16”

1/4”

Remove all old barbed fittings and insert a ½” barbed straight fitting in each of the individual reservoirs

and a ½” barbed elbow into the two end reservoirs. Use ½” blue tubing to connect the reservoirs in a loop

as shown below. The circulating pumping column will pump the nutrient solution into the controller from

the individual WaterFarm reservoirs and circulates it back through the system.

Remove all old barbed fittings and insert a ½” barbed straight fitting in each of the individual reservoirs

and a ½” barbed elbow into the two end reservoirs. Use ½” blue tubing to connect the reservoirs in a loop

as shown below. The circulating pumping column will pump the nutrient solution into the controller from

the individual WaterFarm reservoirs and circulates it back through the system.

4.

8 Gal Controller Bottom Bucket

Air Pump

Circulating Pumping Column

Insert a ½” elbow all the way into the hole that was

drilled in the controller and connect the blue tube

from the circulating pumping column on the inside of

the controller. Feed the airline through the airline

outlet hole and connect to the single output pump.

Insert a ½” elbow all the way into the hole that was

drilled in the controller and connect the blue tube

from the circulating pumping column on the inside of

the controller. Feed the airline through the airline

outlet hole and connect to the single output pump.

3.

13/16”

Using the 13/16” spade bit and template,

mark and drill a second grommet hole in

each WaterFarm reservoir opposite the

original hole and insert a ½” grommet

into each new hole.

Using the 13/16” spade bit and template,

mark and drill a second grommet hole in

each WaterFarm reservoir opposite the

original hole and insert a ½” grommet

into each new hole.

1.

4 Gal WaterFarm Reservoir

Template

13/16”

1/4”

Using the 13/16” spade bit and template,

mark and drill a second grommet hole on

either the left or right side of the controller

and insert a ½” grommet into the hole.

Then use the ¼” drill bit and template to

mark and drill a hole for the air hose outlet

in the controller.

Using the 13/16” spade bit and template,

mark and drill a second grommet hole on

either the left or right side of the controller

and insert a ½” grommet into the hole.

Then use the ¼” drill bit and template to

mark and drill a hole for the air hose outlet

in the controller.

2.

8 Gal Controller Bottom Bucket

Template

Template

Circulating Upgrade Kit

Circulating Upgrade Kit

The WaterFarm 8 Pack Circulating

Upgrade Kit contains everything

needed to reconfigure an 8 Pack and

add nutrient circulation capability to

an existing system. This promotes

even growth and more consistent

results overall.

• Blue Tubing 1/2” x 9’

• Circulating pumping column

• Air Hose 1/4” x 6’

• Single Output Air Pump

Kit Includes:

• 9 1/2” Grommets

• 15 1/2” Straight Barbed Fittings

• 4 1/2” Elbow Barbed Fittings

• Blue Tubing 1/2” x 8”

• 13/16” Spade bit

• 1/4” Drill bit

REQUIRES DRILL

FOR ASSEMBLY

p030409am

Advertising