TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too low

2. Burner orifice clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

3. Residues from manufacturing

processes and logs curing

1. Not enough combustion/ven-

tilation air

1. Turning control knob to HI

or position 5 when burner is

cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Metal expanding while heating

or contracting while cooling

REMEDY

1. Clean burner (see Cleaning

and Maintenance, page 23)

or replace burner orifice

2. Contact local propane/LP or

natural gas company

1. Contact local propane/LP or

natural gas company

2. Clean burner (see Cleaning

and Maintenance, page 23)

or replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 23)

or replace burner orifice

2. Replace damaged burner

3. Replace gas regulator

1. Check burner for dirt and de-

bris. If found, clean burner (see

Cleaning and Maintenance,

page 23)

2. Replace gas regulator

3. Problem will stop after a few

hours of operation

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

1. Turn control knob to LO or

position 1 and let warm up for a

minute

2. Operate burner until air is

removed from line. Have gas

line checked by local propane/

LP or natural gas company

3. Observe minimum installa-

tion clearances (see page 9)

4. Clean burner (see Cleaning

and Maintenance, page 23)

or replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet

cleaners or similar products

1. This is common with most heat-

ers. If noise is excessive, contact

qualified service person

OBSERVED PROBLEM

Burner does light after ODS/

pilot is lit

Delayed ignition of burner

Burner backfiring during

combustion

Slight smoke or odor during

initial operation

Moisture/condensation noticed

on windows

Heater produces a whistling

noise when burner is lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Heater produces a clicking/tick-

ing noise just after burner is lit

or shut off

Advertising