Cp372 introduction – Kontron CP372 User Manual
Page 27
Advertising

CP372
Introduction
ID 25780, Rev. 01
© 2002 Kontron Modular Computers GmbH
Page 1 - 11
25780
.01.VC.021
121/1
11237
P R E L I M I N A R Y
Note:
BEST CASE ACCURACY:
best case calibration (not supported by Kontron)
ACCURACY:
calibration by Kontron (at delivery)
Table 1-5: CP372 Accuracy
OUTPUT
SIGNAL
-
TYPE
and
RANGE
SIGNAL ACCURACY
at 23°C
± % of
FULL SCALE
ACCUMULATING
DEVIATION
% per K
(S and E1 BOARDS)
ACCUMULATING
DEVIATION
% per K
(E2 BOARDS)
BEST CASE ACCURACY
0 V –
5 V
0.05
0.001
0.001
0 V – 10 V
0.05
0.001
0.001
- 5 V – + 5 V
0.05
0.001
0.001
- 10 V – + 10 V
0.05
0.001
0.001
0 mA – 20 mA
0.1
0.002
0.002
ACCURACY
0 V –
5 V
0.05
0.001
0.001
0 V – 10 V
0.075
0.001
0.001
- 5 V – + 5 V
0.075
0.001
0.001
- 10 V – + 10 V
0.1
0.001
0.001
0 mA – 20 mA
0.1
0.002
0.002
Advertising