3 amc bays, 3 amc bays - 9, Amc bay address - 9 – Kontron AT8901 User Manual
Page 40: 10 amc b1 channel assignment - 9, At8901 hardware description

AT8901
Hardware Description
Page 3 - 9
AT8901 User Guide
3.3
AMC Bays
Two AMC bays for standard or custom AMCs with full height and single width are implemented
with B+ connectors.
Following AMC Geographic Addresses are implemented:
Table 3-9: AMC Bay Address
The state of each GA signal is represented by G (grounded), U (unconnected) or P (pulled up
to management power).
AMC
AMC Bay ID
GA [2..0]
IPMB-L Address
1
B1
UGU
7Ah
2
B2
UUG
7Ch
Table 3-10: AMC B1 Channel Assignment
Channel
Region
Connection
0
GbE
Local Base Switch 0/21
1
GbE
Remote Base Switch 0/22
2
SATA/FC
AMC B2, channel 2
3
SATA/FC
RTM, STOR0
4
Fabric
-
5
Fabric
-
6
Fabric
-
7
Fabric
-
8
Fabric
-
9
Fabric
-
10
Fabric
-
11
Fabric
-
12
-
-
13
Extended
RTM, AMC_B1_P13
14
Extended
RTM, AMC_B1_P14
15
Extended
RTM, AMC_B1_P15
16
Extended
RTM, AMC_B1_P16
17
Extended
RTM, AMC_B1_P17
18
Extended
RTM, AMC_B1_P18
19
Extended
RTM, AMC_B1_P19
20
Extended
RTM, AMC_B1_P20