AT8402

Diagnostics running on the Carrier

Page 2 - 11

AT8402 CLI Reference Manual

Failure impact

FUM-00040001 diagnostic code results from inconsistency of memory bank 1.
Impact is loss of update functionality for the IPMC.

FUM-00040002 diagnostic code results from inconsistency of memory bank 2.
Impact is loss of update functionality for the IPMC.

FUM-00040003 diagnostic code results from update failure when using memory
bank 1. Impact is loss of update functionality for the IPMC.

FUM-00040004 diagnostic code results from update failure when using memory
bank 2. Impact is loss of update functionality for the IPMC.

2.6

IPMI Controller

2.6.1

IPMC_SENSORS

Sensor test.
Test group:

Diagnostics

Test case:

ipmc

Test procedure: IPMC_SENSORS
Test host:

Carrier

Test IC:

quickturn

Test mode:

normal

Diagnostic code:

IPMC-00050001 IPMC-000501nn IPMC-000502nn IPMC-

000503nn

Description

This test checks that all sensors shows adequate values. This includes voltage,

temperature, current and fuse sensors. It checks that all values read from sensors are

within given thresholds.

Sequence (regression)

read all sensors from the IPMC.

check that all values are within their thresholds.

Execute

<ipmitool -v sensor list> to get a list witH all sensors.

Possible failures are

the diagnostic code encodes the number of the failed sensor in the last two hexa-
decimal digits.

Failure impact

IPMC-00050001 diagnostic code results of failure to access the IPMC through the
KCS interface. The impact is loss of applications running on carrier host processor.
This impacts at least Ethernet functionality and command line interface.

IPMC-000501nn diagnostic code results from a failure to read the sensor nn.
Impact is loss of the sensor, i.e. the sensor has failed.

IPMC-000502nn diagnostic code results from the sensor nn reading values outside
its defined known-good values, either exceeding thresholds or indicating failure

Advertising