2 ipmc health indicator sensor aggregation – Kontron AT8242 User Manual

Page 62

Advertising
background image

46

AT8242

www.kontron.com

4.3.2.2

IPMC Health Indicator Sensor Aggregation

The following table shows the sensors involved in the Health Sensor Aggregation.

Table 4-19:IPMC Health Indicator Sensor Aggregation

59

IPMC SEL State

Discrete

Specifies SEL status (Cleared/Almost Full/Full)
Sensor type = 10h Event Logging Disable
Event Reading type code = 6Fh Sensor specific, offset 2,4,5 are used
See IPMI v1.5 table 36.3, Sensor type code 10h for sensor definition

60

Jumper Status

Discrete

Reflects on-board jumper presence
Sensor type = D3h OEM (Kontron OEM Jumper Status)
Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are used
See OEM table, Sensor type code D3h for sensor definition

61

IPMI Info-1

Discrete

Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 70h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 70h for

sensor definition

62

IPMI Info-2

Discrete

Internal Management Controller firmware diagnostic
Sensor type = C0h Kontron OEM Firmware Info
Event Reading type code = 75h Kontron OEM Internal Diagnostic
See OEM table, Sensor type code C0h and Event/Reading type code 75h for

sensor definition

IPMI Sensor ID

Sensor Name

5

Temp Inlet

6

Temp Outlet

7

Temp IPMC

8

Temp Switch

9

Temp SO-DIMM

10

Brd Input Power

11

RTM Power

12

Vcc +12V SUS

13

Vcc +5V SUS

14

Vcc +3.3V SUS

15

Vcc +2.5V SUS

16

Vcc +1.5V SUS

17

Vcc +1.2V SUS

18

Vcc +0.75V SUS

19

Vcc +1.2V Early

20

Vcc +5V

21

Vcc +2.5V

22

Vcc +1.1V

23

Vcc +1.05V

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)

Advertising