7 standards, Standards - 12, Introduction am4100 – Kontron AM4100 User Manual

Page 30

Advertising
background image

Introduction

AM4100

Page 1 - 12

ID 36126, Rev. 2.0

P R E L I M I N A R Y

1.7

Standards

The Kontron AMC boards comply with the requirements of the following standards.

Table 1-3:

Standards

COMPLIANCE

TYPE

STANDARD

TEST LEVEL

CE

Emission

EN55022
EN61000-6-3
EN300386

--

Immission

EN55024
EN61000-6-2
EN300386

--

Electrical Safety

EN60950-1

--

Mechanical

Mechanical Dimensions IEEE 1101.10

--

Environmental and
Health Aspects

Vibration
(sinusoidal, operating)

GR-63-CORE
EN300019-2-3
IEC61131-2
IEC60068-2-6

5-150 [Hz] frequency range
1 [g] acceleration
1 [oct/min] sweep rate
10 sweeps/axis

3 directions: x,y,z

Vibration
(random, transporta-
tion)

GR-63-CORE
EN300019-2-2
IEC60068-2-64

5-20 [Hz]: 0.01[g²/Hz] ASD
20-200 [Hz]: -3 [dB] slope
8.8 [m/s² RMS] acceleration
30 [min] test time/axis

3 directions: x,y,z

Shock (operating)

EN300019-2-3
IEC61131-2
IEC60068-2-27

15 [g] acceleration
11 [ms] pulse duration
3 shocks per direction
5 [s] recovery time
6 directions, ±x, ±y, ±z

Permanent Shock
(transportation)

EN300019-2-2
IEC60068-2-29

18 [g] acceleration
6 [ms] pulse duration
100 shocks per direction
1 [s] recovery time
6 directions, ±x, ±y, ±z

Climatic Humidity

IEC60068-2-78

93% RH at 40°C, non-condensing

WEEE

Directive 2002/96/EC

Waste electrical and electronic equipment

RoHS

Directive 2002/95/EC

Restriction of the use of certain
hazardous substances in electrical and
electronic equipment