Am4022 introduction – Kontron AM4022 User Manual

Page 29

Advertising
background image

AM4022

Introduction

ID 1052-0183, Rev. 1.0

Page 1 - 11

Con

nectors

Front Panel
Connectors

•

One USB 2.0 port on a 5-pin, mini USB Type A connector

•

Two Gigabit Ethernet ports on two RJ-45 connectors

•

One Serial port (COMA) with RS-232 signal level on a 10-pin mini
connector (on the front panel version with a COM port)

•

One 20-pin DisplayPort connector (on the front panel version with a
DisplayPort)

Onboard Connector

•

One extension connector for either Serial ATA Flash or an RTC Backup
Battery module

AMC Card-edge
Connector

•

One 170-pin AMC Card-edge connector

Switches

DIP Switches

•

Two DIP switches for board configuration, SW2 and SW3, consisting of
four switches each

Hot Swap

•

One Hot Swap switch

LEDs

Module Management
LEDs

•

LED1 (red):

Out-of-Service LED

•

LED2 (red/green/amber): Health LED

•

HS LED (blue):

Hot swap LED

User-Specific LEDs

•

ULED3 (red/green):

AMC Ethernet port A link signal status,
AMC port 0 (green) + POST code

•

ULED2 (red/green):

AMC Ethernet port B link signal status,
AMC port 1 (green) + POST code

•

ULED1 (red/green):

SATA channels active (green) + POST code

•

ULED0 (red/green):

POST code

Ethernet LEDs

•

Act (green):

Network / Link Activity

•

Speed (green/yellow):

Network speed

Ti

m

er

Watchdog Timer

•

Software-configurable, two-stage Watchdog with programmable timeout
ranging from 125 ms to 4096 s in 16 steps

•

Serves for generating IRQ or hardware reset

System Timer

•

The Intel® QM77 chipset contains three 8254-style counters which have
fixed uses

•

In addition to the three 8254-style counters, the Intel® QM77 chipset
includes eight individual high-precision event timers that may be used
by the operating system. They are implemented as a single counter
each with its own comparator and value register.

IP

MI

Module Management
Controller

•

ARM7 microcontroller with redundant 512 kB Firmware Flash and auto-
matic roll-back strategy

•

The MMC carries out IPMI commands such as monitoring several
onboard temperature conditions, board voltages and the power supply
status, and managing hot swap operations.

•

The MMC is accessible via a local IPMB (IPMB-L) and one host Key-
board Controller Style Interface (KCS)

•

One MMC system EEPROM for FRU data and firmware private data

Hot Swap

The AM4022 has full hot swap capability.

Table 1-2: AM4022 Main Specifications (Continued)

AM4022

SPECIFICATIONS

Advertising