6 mtbf, Mtbf – Kontron COMe-cXLi2 User Manual
Page 19

Kontron COMe-cXLi2 User’s Guide
www.kontron.com
13
»
Maximum heat spreader-plate temperature: -40 to +85°C(*)
»
Non-operating: -40 to +85°C
Note:
*The maximum operating temperature with the heat spreader plate
installed is the maximum measurable temperature on any spot on the heat
spreader surface. You must maintain the temperature according to the
specification above.
Operating (without Kontron heat-spreader plate assembly):
»
Maximum operating temperature: -40°C to +85°C
»
Non operating: -40°C to +85°C
Note:
**The maximum operating temperature is the maximum measurable
temperature on any spot on the module surface. You must maintain the
temperature according to the specification above.
Humidity
»
Operating: 10% to 90% (non condensing)
»
Non operating: 5% to 95% (non condensing)
3.6
MTBF
144628 hours