Jp12, Jp11 – Kontron CP3-BP8-P47-RIO User Manual
Page 11

CPCI Backplane
PD06: CP3-BP8-P47-RIO
RID 24229 PD06, Rev. 01
© 2002 PEP Modular Computers GmbH
Page 11
5.6
System Monitor and Control Connectors JP11 and JP12
This backplane is provided with two connectors for system monitor and control signal interfac-
ing to external devices. Both are 26-contact, male, double pin-row connectors, and have the
same signal pinout configuration. The system management bus (IPMB0), the power supply
monitor and control signals, and push button reset (PRST#) signal are all implemented on
these connectors.
Figure 8: Orientation and Pinout of the CP3-BP8-P47-RIO SMC Connectors JP11 and JP12
1
13
b
a
JP12
1
13
b
a
JP11
Table 9: Pinout of CP3-BP8-P47-RIO
SMC Connectors JP11 and JP12
Pin
Function
Pin Row A
Pin Row B
1
IMPB0_SCL
GND
2
IMPB0_SDA
IMPB0_PWR
3
N/C
GND
4
N/C
GND
5
N/C
GND
6
INH#
GND
7
FAL#
DEG#
8
PRST#
GND
9
GND
V1 SENSE (+5V)
10
V2 SENSE (+3.3V)
SENSE RTN
11
V3 SENSE (+12V)
GND
12
V1 SHARE (+5V)
V2 SHARE (+3.3V)
13
V3 SHARE (+12V)
GND