Radiance vent-free gas heater, Warning, Install on/off switch – Vermont Casting thru 3379 User Manual

Page 12: Thermostat connection (optional)

Advertising
background image

12

Radiance Vent-Free Gas Heater

20004555

MOTOR

SNAPSTAT

ON/OFF

RHEOSTAT

WHT

WH

T

BLK

BLK

BLK

GR

N

BLK

POWER

ST196

FK26 fan diangram

11/99

Fig. 15 #2767 / FK26 Fan Wiring Diagram

Disconnect power

before servicing.

ST196

The optional fan kit is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong outlet. Do not cut or
remove the grounding prong from this plug.

WARNING

NOTE: If you are installing the fan kit after the stove is
in its final location, follow same steps mentioned previ-
ously with the exception of disengaging only the right
side of the outer shroud.

ST347a

JUV

FK28

rheostat install

9/21/00

Rheostat

Retaining Nut

Control Knob

ST347a

Fig. 14 Attach rheostat to control panel. Valve may look dif-
ferent.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove

shroud using two screws and existing holes in
shroud. (Fig. 16)

2. Run wires down back of stove, under bottom of rear

shroud to valve.

3. Attach wires to valve terminals. (Fig. 17)

TP

TH

TPTH

ST228

attach switch

wires to valve

12/99

ST228

Fig. 17 Attach switch wires to valve

.

ST315

attach switch assy

1/31/00 djt

Existing

Holes

Switch As-

sembly

Screws

ST315

Fig. 16 Attach switch assembly to rear shroud.

Thermostat Wire / Gauge

Maximum Run

18

40 feet

20

25 feet

22

16 feet

Thermostat Connection (Optional)

Use only a thermostat rated for 500 - 750 millivolts.
Do not use low voltage (24V) thermostats.

Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.

1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4” female connectors.

2. Connect the thermostat wires to the valve. (Fig. 17)