R E L I A N C E C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

PRO DUCT USE

The FRP pressure plate m ay be installed on Reliance or the Reliance-TC curtain wall system using 1"

glazing. Please reference the curtain wall installation m anual for the appropriate product for

fabrication, assem bly and installation of the wall system . This m anual is to be used in conjunction with

the curtain wall m anual to provide specific instructions as it relates to the fiberglass pressure plate and

its usage. If the FRP pressure plate is to be used for glass sizes larger than 40 sq. ft., glazing

thickness greater than 1" or for special applications please contact O ldcastle BuildingEnvelope for

review of the application and recom m endations.

The FRP pressure plate is intended for installation by glazing professionals with appropriate

experience. Subcontractors without experience should em ploy a qualified person to provide field

instruction and project m anagem ent.

O ldcastle BuildingEnvelope does not control the application or selection of its product config urations,

sealant or glazing m aterial and assum es no responsibility thereof. It is the responsibility of the owner,

architect and installer to m ake these selections in strict com pliance with applicable laws and building

codes.

Consult sealant m anufacturer for review and recom m endation of sealant application. Follow

sealant m anufacturer’s recom m endations and literature for proper installation.

The air and water perform ance of the FRP pressure plate when used in conjunction with any of

O ldcastle BuildingEnvelope Reliancecurtain wall system s is directly related to the com pleteness

and integrity of the installation process. To insure top perform ance for this system , particular attention

should be given the following procedures:

1. Surfaces to be sealed should be cleaned with isopropyl alcohol or solvent and dried as

recom m ended by sealant m anufacturer to rem ove all dirt and cutting oils. Sealant at shear

blocks should be a m inim um 3/16” diam eter nom inal placed com pletely around the top, face

and bottom of the shear block without gaps in the sealant. Exposed surfaces should be

cleaned after installing the horizontal. Inspect joint for com plete sealant contact, especially

where the horizontal m eets the face of the vertical m em ber. Repair joint as required.

2. The interior glazing gasket should be installed so as to avoid stretching, buckles or tears.

Corners m ust be cut square, sealed and butted together. To avoid dam age to gasket and

corner joints during glazing, glass should be level and straight during installation.

Variations on the details shown are inevitable and are not the responsibility of O ldcastle

BuildingEnvelope when drawn by others. O ldcastle BuildingEnvelope strongly encourages its

custom ers to utilize O ldcastle BuildingEnvelope supplied calculations and shop drawings.

FRP PRESSURE PLATE

®

®

®

®

®

®