iCharger Synchronous Balance Charger/Discharger 206B


LiPo Termination
Voltage 4.20V

LiFe Termination
Voltage 3.60V
Delay 0min

Lilo Termination
Voltage 4.10V

-

Dec

+

Inc

-

Dec

+

Inc

-

Dec

+

Inc

Pb Termination
Voltage 2.40V

-

Dec

+

Inc

Inc

Dec

Inc

Dec

Inc

Dec




Termination voltage for LiFe. Adjust LiFe‘s charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the ―Voltage‖ value,
then press Dec and Inc to adjust the termination voltage.

Range: 3.40V – 3.90V, Step: 0.01V (3.60V, default)


Termination voltage for Lilo. Adjust Lilo‘s charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the ―Voltage‖ value,
then press Dec and Inc to adjust the termination voltage.

Range: 3.90V – 4.20V, Step: 0.01V (4.10V, default)


Termination voltage for LiPo. Adjust LiPo‘s charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the ―Voltage‖ value,
then press Dec and Inc to adjust the termination voltage.

Range: 4.00V – 4.30V, Step: 0.01V (4.20V, default)


Termination voltage for Pb. Adjust Pb‘s charge termination voltage. Press
Start/Enter for more than 3 seconds to blink the ―Voltage‖ value, then
press Dec and Inc to adjust the termination voltage.

Range: 2.20V – 2.50V, Step: 0.01V (2.40V, default)

Note: The Termination voltage controls the transition from Constant
Current (CC) to Constant Voltage (CV) charging for LiXx and Pb
chemistries. It also defines the per-cell limit for cell overvoltage detection.

If you change the default termination voltage, the charge and discharge
setting screen will note this difference by alternatively blinking battery‘s
type and setting voltage value.