There are no components within the DLS unit that, in their normal operation, produce arcs or sparks. However, all 
electronic devices have some potential for generating sparks in the event of failure. Therefore, never install this 
device in the same compartment with flammable items such as gasoline or batteries.
INSTALLATION GUIDELINES
MOUNTING LOCATION
The DLS battery charger/power supply can be mounted in 
any position within an enclosed or interior compartment. 
Provide sufficient air space to allow unrestricted airflow in 
and around the unit. 
DLS INSTALLATION
Disconnect the positive side of the battery before installation. 
Connect the positive (red) and negative (black) terminal lugs to 
battery or load. Always use the proper size wire based on the 
amperage of the converter and the battery. When connecting to 
a battery, a breaker should be installed within 18” of the battery, 
connecting the battery positive to the line side of the breaker, 
and the DLS to the load side. Connect “Chassis Bonding Lug” 
on the DLS to vehicle chassis or other grounding source.
240 VOLT A.C. INPUT
The unit is equipped with a three-prong A.C. input cord for 
connection to the 220VAC power source. The cord is rated 
250VAC, and is 3 feet long from the input side of the unit. 
REVERSE POLARITY FUSES
The DLS Battery Charger/Power Supply is protected 
against reverse polarity on the DC output. If a battery 
or the DLS is hooked up incorrectly, the fuses will blow 
and can be easily replaced. Always use the same size 
and style fuse that came with the converter. To change 
the fuses, use a screwdriver to loosen the screws and 
remove the fuses. Always replace the fuses with the 
same type and rating. After inserting the new fuses, 
tighten the screws firmly. 
Rev 010510
68357-220
TWO-STEP VOLTAGE JACK
The two-step voltage jack (located on the top of the DLS on the fan-end of the unit) 
allows switching from a long-term float voltage to an increased quick-charge voltage. 
When the included dual voltage plug is inserted in the jack*, the voltage increases for 
faster charging. When the plug is removed, the voltage drops to rated nominal voltage 
to reduce battery water loss. 
WARNING: To avoid battery damage, remove the Dual
Voltage Plug when quick-charging is complete. NOTE: If the DLS is equipped with 
an internal IQ4 smart charger, two-step charging is not needed and the Dual Voltage 
Jack is disabled.
CHARGE CONTROL
THE IQ4 LED INDICATOR
(ONLY ON DLS MODELS WITH INTERNAL IQ4)
DLS Models with an internal IQ4 smart-charger give the user the benefit of automatic 
Bulk, Absorption, and Float stage charging. This increases the charging capacity of the 
DLS charger, decreases charge times and insures proper and safe battery charging 
without over-charging. The green LED on the fan end of the DLS will indicate which 
charging phase the DLS unit is currently in. When the unit is first activated, the LED will 
flash as it reads the number of cells in the battery. The unit will then proceed directly 
to the Bulk charging or Float charging phase depending on the charge status of the 
battery. Use the LED CODE TABLE for reference when checking the LED. Units that do 
not have an internal IQ4 smart-charger can easily install an external IQ4 that plugs into 
the available Dual Voltage Jack. Contact Customer Service for more information.
*Location of the Dual Voltage Jack may vary depending on model.