Ring Communications DXC901 User Manual
Page 15

SEPTEMBER 2003
DIGITAL EXCHANGE CONTROLLER
DXC901
B15
RING COMMUNICATIONS INC.
calling station for the annunciator display whose network address is found
in A
NNUNCIATOR
1
A
DDRESS
. The DXC901 will dial on behalf of this SAR’s
S
UBSCRIBE R
A
DDRESS
if the A
NNUNCIATOR
1
A
DDRESS
attempts to answer
one of it’s incoming events. (See Figure B5 & Figure B6 for examples of
typical S
UBSCRIBER
T
YPE
2 configurations).
3 =
Sub-Master, a master station with Supervision, Alarm, Call, Fault capability
in the Crisis system, and regular master station intercom dialing. The
DXC901 will treat this station like a S
UBSCRIBER
T
YPE
1 with the exception
that it will allow the station to dial if the DC Shift is within the parameters
below for dialing. (See Figure C11 for a typical S
UBSCRIBER
T
YPE
3
configuration).
A S
UBSCRIBER
T
YPE
3 Sub-Master is one that will provide the following DC
Shift Length on the 1 and 2 voice pair used by DXC901 to determine what
event is occurring at the Sub-Master:
EVENT
DC SHIFT LENGTH
DIALING
< 0.9 seconds
CALL
between 0.9 and 1.1 seconds
ALARM
> 1.1 seconds
4 =
Supervised substation using an input for CALL, an input for Music Channel
Step, and an input for Volume Step. The DXC901 will treat this station like
a S
UBSCRIBER
T
YPE
1 with the exception that it will dial a “1" or a “2" on behalf
of the substation if the DC Shift is within the parameters below.
A S
UBSCRIBER
T
YPE
4 Substation is one that will provide the following DC
Shift Length on the 1 and 2 voice pair used by DXC901 to determine what
event is occurring at the Substation:
EVENT
DC SHIFT LENGTH
DIALS “1"
100 milliseconds ± 50 milliseconds
DIALS “2"
200 milliseconds ± 50 milliseconds
CALL
1 second ± 100 milliseconds
ALARM
> 1.1 seconds
In Tridex SVT, program Direct Dialing 949 for button number 1, and Direct
Dialing 948 for button number 2 for this particular substation. Program
direct dial table number 1 for both channels in the SVT programming. 948
is the facility code to step through Program Distribution Channel Volumes.
949 is the facility code to step through Program Distribution Channels. The
Program Distribution Mode must be set to Mode A in order for this to work.
(See SVT
P
ROGRAMMING
M
ANUAL
for detailed explanations on D
IRECT