11

Nothing comes close to a Cobra

®

Power Consumption

For each piece of equipment you will be operating from the inverter, you must
determine the battery’s reserve capacity (how long the battery can deliver a
specific amount of current — in automotive batteries, usually 25 amperes) or
ampere-hour capacity (a measure of how many amperes a battery can deliver
for a specified length of time).

Example – Reserve capacity: a battery with a reserve capacity of 180 minutes
can deliver 25 amperes for 180 minutes before it is completely discharged.

Example – Ampere-hour capacity: a battery with an ampere-hour capacity of
100 ampere-hours can deliver 5 amperes for 20 hours before it is completely
discharged.

To Determine the Battery Ampere-Hour Capacity You Require:

1. Determine how many watts each piece of equipment consumes. This can normally

be found on the product label. If only the current draw is given, multiply the current
draw by 115 to get the watt consumption.

2. Estimate the time (in hours) that each piece of equipment will be running between

battery charging cycles.

3. Calculate the total watt-hours of energy consumption (power x operating time) using

the average power consumption and the total estimated running time (in hours).
Power x Operating Time = Watt-Hours.

4. Divide the watt-hours by ten (10) to determine how many power supply’s

(12 volt) ampere-hours will be consumed.

10 English

CAUTION Do not connect the inverter and another AC source (such as a
generator or utility power) to the AC wiring at the same time. The inverter
will be damaged if its output is connected to AC voltage from another
source. Damage can even occur if the inverter is switched Off.

CAUTION Do not connect the inverter to an AC branch circuit that has high-
power consumption loads. It will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than 800 watts.

CAUTION Loose connectors result in excessive voltage drop and may cause
overheated wires and melted insulation.

CAUTION Reverse polarity connections (positive to negative) will blow internal
fuses in the inverter and may permanently damage the unit. Such damage is
not covered by the warranty.

CAUTION Remove any jewelry (watch, ring, etc.). Be careful not to short
circuit the battery with any metallic object (wrench, etc.).

WARNING 115 volt AC power is potentially lethal. Do not work on AC wiring
when it is connected to the inverter (even if it is switched Off) unless the DC
power source is physically disconnected from the inverter. Also, do not work
on AC wiring if it is connected to another AC power source such as a generator
or the utility line.

WARNING You may observe a spark when making the connection because
current can flow to charge the capacitors in the inverter. Do not make this
connection in the presence of flammable fumes
. Explosion or fire may result.
Thoroughly ventilate the battery compartment before making this connection.

Installation

Connecting Cables

Installation

Power Consumption

300 Watts x 15 minutes
= 75 Watt-Hours

115 Watts x 3 hours
= 345 Watt-Hours

Blender

TV/VCR (up to 25")

100 Watts x 2 hours
= 200 Watt-Hours

Laptop