Jumper Selections

Parking Light Polarity. Selects the polarity (+/-) for the output of the on-board Parking Light

relay.

Pin 1 + Pin 2 = positive
Pin 2 + Pin 3 = negative

Dome Light Polarity. Selects the polarity (+/-) for the output of the on-board Illuminated

Entry/Exit relay.

Pin 1 + Pin 2 = positive
Pin 2 + Pin 3 = negative

Door Lock Pulse Width. Selects between a 1-second and a 4-second output for door locking

and unlocking. Set to 4 seconds when interfacing into vehicles equipped with vacuum door
locking systems.

Ignore Delayed Domelight. For use with vehicles equipped with a timed dome light circuit that

stays on after door has been closed. When the jumper is on, the system will ignore the
dome light circuit during arming to prevent the system from responding with an open zone
indication each time the system is armed.

Passive Door Locking. When the jumper is on, the system will automatically lock the doors with

Auto Rearm and Passive Arming.

Horn Honk / Arming Output. Selects between pulsed or constant output for the Orange/blue

wire.

Logic Sensor Motion Sensitivity. When the jumper is off, the system will respond to shock

only. When the jumper is set to on, the system will respond to both shock and motion.