MAINTENANCE & SERVICE

6

TROUBLESHOOTING GUIDE

7

Maintaining Your
Inverter

Your CPI 300 requires very
little maintenance to keep it
operating properly. The exterior
of the unit should be cleaned
periodically with a damp cloth
to prevent accumulation of
dust and dirt. At the same
time, tighten the screws on
the DC input terminals. Keep
vents and fans free from dust
or debris.

Service

You can receive technical
assistance with your unit
through one of our customer
support services:
• Automated Help Desk

is available 24 hours a day,
7 days a week at
773-889-3087.

• Customer Service Operators

are available at
773-889-3087 Monday
through Friday, 8:00 a.m. to
6:00 p.m. CST.

• Questions can be faxed to

773-622-2269.

• Automated Technical

Assistance is available
24 hours, 7 days a week
via e-mail at:
[email protected].

• On-line answers to

frequently asked questions
can be found at:
www.cobra.com

8

Problem/

Possible Solution

Symptom

Causes

Low output voltage

Overload

Reduce the load.

No output voltage

Low input

Recharge battery.

voltage

Check connections

and cable.

Short circuit or

Check AC wiring for short

wiring error

circuit or improper polarity.

No output voltage High input

Make sure the inverter

and ”fault“

voltage

is connected to a

indicator is lit

12 volt battery.

Check regulation of

charging system.

No output voltage

Thermal

Allow inverter to cool down

when load is in

shutdown

Improve ventilation—

excess of 300 watts

make sure ventilation

or 2.6 amperes

openings in the inverter

aren’t obstructed. Lower

ambient temperature.

Low battery

Poor DC wiring,

Use proper cable.

alarm sounds

poor battery

Ensure good connections.

continuously

connection

Use new battery.