Tycon Power TP-SCPOE-24xx-HP Series User Manual

Page 3

Advertising
background image

User’s Manual

TP-SCPOE-24XX(-HP) Series


Panel Description:







Item

Name

Descriptions

1

POE :

PoE power input indicator: the LED lights when the PoE input jack
(the lower jack) has 36V~57V input.

2

SOL :

Solar power input indicator: the LED lights when SOL terminal is
connecting to a solar panel.

3

CHA :

Charging indicator: the LED lights when BAT terminal is connected
to battery and charging, the charger power may from solar or PoE.

4

LOA :

Loading indicator: the LED lights when the rear panel output
terminal is connecting to a device and offering power.
The LED always on when power ready.

5

REV :

Battery polarity reverse indicator: the LED lights when the battery
polarities are reversed. (detail description see Sec. 5.1)

6

IN :

PoE Input Jack: the lower RJ45 jack, used for PoE input. Allowed
input voltage 36~57V

7

OUT :

PoE Output Jack: the upper RJ45 jack, used for PoE output; Output
voltage depends on what model you selected.

8

Fuse

Fuse: for output over current protection, limiting the battery output
current <= 10A. (If solar panel or PoE source is installed before the
battery, and if the polarities of battery are reversed, then the fuse will
be burnt.)

9

SOL :

Solar Panel Terminal: used to connect the solar panel.

10

BAT :

Battery terminal: used to connect the battery.
NOTE: ALWAYS CONNECT THIS TERMINAL FIRST AND
DISCONNECT LAST.

11

LOA :

Load Terminal: The output voltage is the same as battery voltage.
Maximum voltage clamped at 24.5V.

Advertising