NOTICE:

1.

DON’T CONNECT THE PS TO 24V BATTERY. The PS was designed for 12V

system. Connection to the wrong battery will damage the PS.

2.

THE AC SWITCH MUST BE TURNED OFF AT ANY TIME WHEN THE

BATTERY IS CHANGED.

3.

Select the correct battery type on the panel, wrong selection will damage the

battery or it will not fully charge the battery. Do not change the battery type

selector when charging.

4.

The model has a 6 amp AC input fuse inside of the unit. To replace the fuse you

should remove the old fuse by opening the case and replace it with a new 6 amp

fuse.

5.

The cables for battery connection or device to the PS should be 14AWG min.

Please keeping the connect points clean to avoid spark or electrical leakage.

6.

Use the proper voltage solar panel or wind turbine for the connection, no voltage

of over 18V.

7.

When connecting a solar panel or wind turbine controller to the PS, please make

sure of the correct polarity.