Vetter Decon Showers 0.3 bar/4.35 psi

Page 5/7

Now connect the constructionsite compressor adaptor to the sup-
port frame. Attach the quick-action coupling (3) to the connection
hose of the pressure regulator and open the hand valve of the
pressure regulator slowly.
It is also possible to deflate the support frame with a blower with
deflate function. Follow the operating instructions of the blower.

After deflation and before packing, the

valve must be unlocked again in order to

guarantee perfect inflation when it is next

used!

4.

Care and Maintenance

The Decon Showers 0.3 bar and its equipment is to be cleaned
after use. Cleaning of the Decon Showers is normally carried out
with warm water with a soap solution and then dried at room
temperature. Cleaning with high pressure hot water devices must
not be carried out under any circumstances. If necessary, conta-
minated showers are to be decontaminated with suitable disin-
fection agents. DIN 7716 is to be observed when storing for long
periods of time

5.

Test

The inflation fittings and the Decon Showers 0.3 bar are to be che-
cked for a perfect and orderly condition each time before and af-
ter use:

9

The parts of the stiffening frame are free of damage, e.g. tears,

cuts, piercings, splits, hard or soft areas caused by chemical or

thermal effects.

9

The PVC foldable container is free of damage, e.g. tears, cuts,

piercings, splits, hard or soft areas caused by chemical or ther-

mal effects.

9

Visual and operational check of the inflation connection and

the blower including the accessories.