Vetter test equipment for lifting bags, 3 safety instructions, Preparations for the test – Vetter Lifting bags 1 bar (14.5 psi) Test Equipment User Manual

Page 6

Advertising
background image

Vetter Test Equipment for Lifting Bags

Page 5/28

1.3 Safety instructions

Due to the fact that when testing pressure containers failure of
the wall supports must be taken into account, then a certain dis-
tance to persons, objects and buildings must be maintained.
A pressure test must only be carried out after a visual test and
function test has been carried out without any defects being
found. Basically, pressure testing should be carried out in outside
open spaces. The pre-specified personal protection equipment/
clothing is to be worn according to UVV.

2.

Preparations for the test

Check the test equipment to see if the individual parts are com-
plete and in perfect condition.
If necessary clean the lifting bags/mini lifting bags/S.Tec lifting
bags with warm soapy water and dry at room temperature.
Check the bag kits to see if the individual parts are complete and
in perfect condition.

3.

Testing the lifting bags 0.5 bar and 1 bar

3.1 Test intervals

9

After each opeation/period of use

Visual test by the user

9

Yearly test

Visual test and function test by a specialist according to the

preliminary stipulations in GUV-G 9102

9

Every 5 years, after repair or if there is any doubt about

safety

Pressure test according to GUV-G 9102 Section 4.1.1.2 (only to
be made by the manufacturer)

3.2 Function test of the inflation device

3.2.1 Required test equipment

9

Blind coupling 0.5 bar

9

Blind coupling 1 bar

9

Test manometer 0.5/1 bar

Advertising