6.

Elimination of defects

Defect

Cause

Remedy

Suction motor

does not run

Protector switch has cut

off

Reactivate protector.
Call specialist if it switches off again.

No voltage at the mains

Check socket

Connection cable defec-

tive

Exchange cable*

Motor defective

Exchange motor*

Suction motor runs

but equipment

does not suction

Float ball has closed the

suction opening

Switch off motor, release float ball

Suction line is blocked

Clean suction line

Motor head turbine is

defective

Carry out maintenance*

Suction motor

runs but suction

power too low

Equipment draws outside

air

Check the adapter and motor head

for correct seating

Sealing is defective

Change sealing

Suction line is blocked

Clean suction line

Suction height is too large Position equipment to suction height

*only by a qualified electrician

Should the defect remain despite the above information then contact an authorized representative or Vetter GmbH.

7.

Technical data

Set Oil-Water-Debris Aspirator Art.Nr.: 2200000804

Unit

Data

Suction power (air)

l/min.

3,030

cu.ft./min.

107

Suction power (water)

l/min.

160

cu.ft./min.

5.7

Vacuum pressure

mm WS

2,392

psi

3.5

Current consumption of motor head

Amps

4.6

Power consumption of motor head

Watts

1,000

Voltage of motor head

V/Hz

240/50/60

Capacity of container

l

100

cu.ft.

3.53

Dimensions of aspirator base equipment

(LxWxH)

cm

86 x Ø 62

inch

34 x Ø 25

Weight (set for base equipment), ca.

kg

30

lbs

66

Noise level

dBA

84.4

Protection class : I

Protection category : IP 44

All rights reserved for technical changes within the scope of product improvement.