Ovens Humidity with
Microprocessor Controls
FL-2267
Rev. 8 (1/05)
Page
9 of 13
5925 Heisley Road
• Mentor, OH 44060-1833
877/CRES COR (273-7267)
• 440/350-1100
Fax: 440/350-7267
• www.crescor.com
HOW TO ADJUST THE DOOR LATCH:
1. For vertical (up and down movement)
adjustment:
a. Loosen (2) screws located in magnetic
strike.
b. Move strike up or down for alignment
to magnet on latch.
c. Tighten screws to secure
2. For horizontal (greater or lesser magnetic
draw) adjustment:
a. Loosen (4) screws in door latch.
b. Move latch forward or backward to
adjust magnetism.
c. Tighten screws to secure.
HOT UNIT REMOVAL:
1. Disconnect power cord from wall outlet.
2. For half-size model: CO151HW Series,
remove screws around top cover.
3. Disconnect the yellow cord between top and
bottom, in the back of the cabinet (see
Figure 2).
4. Lift off Hot Unit.
FIGURE 2
Hot Unit Removal
REPLACEMENT PARTS: Include all information on nameplate when ordering parts.
Cabinet Replacement Parts
MODEL PRFIX CO-151, RO-151 (“Q” SERIES)
DESCRIPTION
-FPWUA (12), (18)
-FWUA (12), (18)
-FW1332
-HWUA6
-XWUA5
Hot Unit, 208V, 1 Ph
HU675013Q1
HU675025Q1 HU675029Q1
HU675037Q1
HU675037Q1
Hot Unit, 208V, 3 Ph
HU675015Q1
HU675027Q1 HU675031Q1
HU675039Q1
HU675039Q1
Hot Unit, 240V, 1 Ph
HU675014Q1
HU675026Q1 HU675030Q1
HU675038Q1
HU675038Q1
Hot Unit 240V, 3 Ph
HU675016Q1
HU675028Q1 HU675032Q1
HU675040Q1
HU675040Q1
Door Latch Kit
1006-120-001
1006-120-01
1006-120-001
1006-120-01
1006-120-01
Door Strike
1006-120-02
1006-120-02
1006-120-02
1006-120-02
1006-120-02
Door Hinge
0519-074
0519-074
0519-074
0519-074
0519-074
Door Assembly
1221-525
1221-525
1221-543
1221-525
1221-545
Door Gasket
0861-185
0861-185
0861-184
0861-185
0861-250
Angles or Racks
0621-281-SS
0621-281-SS
1104-108
0621-281-SS
0621-281-SS
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE, continued