Gas supply requirements, Ventilation – CDA HCG601 User Manual

Page 8

Advertising
background image

Gas Supply Requirements

IMPORTANT: THIS APPLIANCE SHOULD BE FITTED BY A GAS SAFE REGISTERED FITTER OR OTHER SUITABLY
QUALIFIED PERSON.

This installation must comply with the Gas Safety (installation and use) Regulations 1984.

This appliance is category II2H3+ and is designed for use in the UK and Ireland. The installation must comply with the

Gas Safety (installation and use) Regulations 1984.

The CDA Group Ltd is not legally able to provide any assistance in the installation of gas appliances except to Gas

Safe registered installers. Any Gas Safe registered fitter requiring help must provide their name, address and registration
number. Information supplied will be validated before help is provided.

This appliance is suitable for conversion to Liquid Petroleum Gas (G30 or G31). A kit is provided. Do not attempt to

fit the conversion kit yourself.

This appliance is adjusted for natural gas (G20) at 20mbar only.

In the event that this appliance is not installed in accordance with the above requirements, the appliance may be

disconnected from the mains gas supply until any faults are rectified; this is a legal requirement.

This appliance should be installed using 15mm copper pipe connected via a shut-off valve in an adjacent unit. The shut-off

valve needs to be accessible in an emergency or for service purposes.

This appliance must not be connected to a combustion gas recovery scavenging system

The connection to the gas supply must comply with all current regulations in force.

We are not legally able to offer advice on the installation of gas appliances to non Gas Safe registered personnel.

Ventilation

All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in
addition to a window (see below).

This unit must not be used in a room which is less than 5m

3

. The following table details the requirements based on the

kitchen volume (L x W x H) in m

3

.

The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in the
same room, consult the relevant British Standard (BS5440) or Gas Safe document.

Room Volume (m

3

)

5

6 to 10

6 to 11

11 or more

Air Vent Required (cm

3

)

100

50

No permanent vent required if a door opens to the outside

None required