Distributed in the U.S.A. and Canada by

Arterra Distribution

Sales (574) 294-8997

Warranty Service (877) 294-8997

Fax (574) 294-8698

TM

OEM Installation Manual

For use with WFCO ULTRA III Power Center

Model WF-8712P and WF-8725P

4

IN

S

T

A

L

L

A

T

IO

N

IN

S

T

R

U

C

T

IO

N

S

For proper wire sizes and torque requirements, refer to the label on the
door assembly.

CHASSIS GROUND WIRE
AC GROUND TERMINAL BAR

GREEN WIRE (FROM CONVERTER)

BLACK WIRE (FROM CONVERTER)

WHITE WIRE (FROM CONVERTER)


AVAILABLE FOR BRANCH CIRCUIT
PIGTAIL TO BRANCH CIRCUIT

MAIN BREAKER

MAIN BREAKER

RETAINING

CLIP TO MAIN

BREAKER HOLD

DOWN

DOOR (PART OF THE DOOR ASSEMBLY)

30

ON

OFF

HOT WIRE

GROUND WIRE

NEUTRAL WIRE

REVERSE BATTERY

PROTECTION FUSE

(Figure. 2)

FUSE

BATTERY

CIRCUIT

RED WIRE

1
2

3

4

1.97?

8.07?

1.77?

DOOR

CONNECTED TO

BRA

NCH CIRCUIT

15

BLACK WIRE
(TO AC SHORE - HOT)

AC NEUTRAL TERMINAL BAR