Reverse Battery Protection
This feature prevents permanent damage to the converter from an incorrect
battery connection.

Automatic Cooling Fan
The fan is variable speed and current controlled.

Electronic Current Limiting
Automatically shuts down power during overload or short-circuit conditions.
Automatically returns to normal operation after conditions are corrected.

DC Fuses (12 Volts)
- Eleven 12 Volt circuits (including two circuits for slideouts)
- Maximum of 30 Amp fuse for DC circuits 10 and 11 (all others max. 20 A)
- Reverse battery protection fuses; replace with
ATC “Littelfuse ” Type 257 fuse

AC Circuit Breakers (120/240 Volts)
- One 30 Amp Main circuit and a maximum of five 20 Amp Branch circuits

UL -Listed Main Circuit Breakers, rated for 120 V, maximum 30 A

Manufacturer
Cutler Hammer
Thomas Betts
ITE/Siemens
Square D

Murray

Model/Cat. No./Type

Type BR and C

Type TB or TBBD

Type QP or QT
Type HOM or HOMT

Type MP-T or MH-T

Acceptable circuit breakers are as follows:

UL-Listed Branch Circuit Breakers, rated for 120 V, maximum 20 A

Manufacturer
Cutler Hammer
Thomas Betts
ITE/Siemens
Square D

Murray

Model/Cat. No./Type

Type BR and C, Type BRD BD and A

Type TB and TBBD

Type QP or QT
Type HOM and HOMT

Type MH-T or MP-T

Acceptable circuit breakers are as follows:

-
type designation, and equal or greater interrupting rating, not to exceed 30 A
- “Short-Circuit-Current” rating for the breaker should be 10,000 A

A replacement or additional circuit breaker shall be of the same manufacturer,

®

General Consumer Information

TM

®

This product should be installed by an experienced technician.
CAUTION
and care must be taken when servicing this equipment.
To prevent severe shock or electrocution consult your servicing dealer.
No serviceable parts.

CAUTION

!

!

WARNING

!

!

CAUTION

!

!

®

This unit employs components that tend to produce arcs or sparks.

To prevent fire or explosion, do not install in compartments

containing batteries or flammable materials

To prevent fire, do not cover or obstruct ventilation openings.

Do not mount in zero-clearance compartment.

Overheating may result.

For continued protection against risk of fire, or electric shock

replace only with same type and ratings of fuse.

(LP gas).

Check on a monthly basis the fluid level in any battery connected to RV
charging system.

This product is not ignition protected and should not be installed in an
LP compartment.

CAUTION

!

!

Installation and Servicing of the WFCO WF-8900 Series Power Center