OEM Installation of the WFCO WF-9900 Series Power Center

Select a mounting location near the shore power and battery (batteries)
and cut a rough opening 1/8? wider than the box to allow the power
center to slide in easily. M

During the manufacturing process, be sure that all converter openings
are protected from debris falling into the unit as this could cause the
components to short out. (This is a non-warranty item.)

NOTE: If the reverse battery protection fuses are blown during
installation, be sure that the battery has been connected properly, then
replace the fuses with ATC “Littelfuse ” Type 257 with the same
rating as the original.

This product is not ignition protected and should not be installed in an
LP compartment.

For proper wire sizes and torque requirements, refer to the label on the
back of the door assembly.

ount in an area where the owner is unlikely

to store items, as this could reduce clearance requirements, obstruct
ventilation openings and affect the performance of the converter.
Select a mounting location that is appropriate to prevent excessive
heat, water, moisture, dust and dirt entering the unit installed. All
installations, shouldbe tested for overall performance.

®

TM

WARNING

!

!

CAUTION

!

!

This unit employs components that tend to produce arcs or sparks.

To prevent fire or explosion, do not install in compartments

containing batteries or flammable materials

For continued protection against risk of fire, or electric shock

replace only with same type and ratings of fuse.

(LP gas).

3

IN

S

T

A

L

L

A

T

IO

N

I

N

S

T

R

U

C

T

IO

N

S

TM

Breaker Filler Plates:

Manufacturer:

EATON

ITE/Siemens

Square D
Murray

Model/Cat. No./Type:

Type BR
Type QP or QT
Type HOM
Type MH or MP

Manufacturer:

ITE/Siemens

Square D

Murray

Model/Cat. No./Type:

Type BRD

Type QP or QT
Type HOMT
Type MHT or MPT

Manufacturer:

WFCO

Model/Cat. No./Type

FP-01 or FP-01B

Max. Main Circuit Breaker Size: 50 Amp two pole or
Equivalent. Note: Use only 2-pole circuit breakers for Main Circuit
breaker.

Max. Branch Circuit Breaker Size: 20 Amp or 20 Amp Two Pole

A replacement or additional circuit breaker shall be of the same
manufacturer, type designation, and equal or greater interrupting
rating.
For Breaker tightening torque ratings, refer to Circuit breaker.

Neutral and Ground wire size refer to the label on the door

.

assembly

EATON

AC Circuit Breakers (120/240) UL Listed