WFCO WF-9800 Series User Manual

Page 7

Advertising
background image

3

IN

S

T

A

L

L

A

T

IO

N

I

N

S

T

R

U

C

T

IO

N

S

TM

WF-9800 Series Converter Dimensions

E

A: 7.50? (WF-9835)
8.76? (WF-9845, 9855)
10.26? (WF-9865, 9875)

B: 5.53? (WF-9835)
6.79? (WF-9845, 9855)
7.52? (WF-9865, 9875)

C: 1.97? (WF-9835/45/55)
2.74? (WF-9865/75)

D: 5.70? (WF-9835)
5.94? (WF-9845, 9855)
6.30? (WF-9865, 9875)

E: 3.94? (WF-9800 Series)

A

B

C

Dimensions

D

C

C

CHASSIS
GROUND

REVERSE POLARITY
FUSES USED:
WF-9835 - 35 Adc
WF-9845 - 30/30 Adc
WF-9855 - 35/35 Adc
WF-9865 - 40/40 Adc
WF-9875 - 40/40 Adc

2

IN

S

T

A

L

L

A

T

IO

N

IN

S

T

R

U

C

T

IO

N

S

TM

OEM Installation of the WFCO WF-9800 Series Power Center

Select a mounting location near the shore power and battery (batteries).

M

During the manufacturing process, be sure that all converter openings
are protected from debris falling into the unit as this could cause the
components to short out. (This is a non-warranty item.)

NOTE: If the reverse battery protection fuses are blown during
installation, be sure that the battery has been connected properly, then
replace the fuses with ATC “Littelfuse ” Type 257 with the same
rating as the original.

This product is not ignition protected and should not be installed in an
LP compartment.

For proper wire sizes and torque requirements, refer to the label on the
back of the unit.

ount in an area where the owner is unlikely to store items, as this

could reduce clearance requirements, obstruct ventilation openings
and effect the performance of the converter.
Select a mounting location that is appropriate to prevent excessive
heat, water, moisture, dust and dirt entering the unit installed. As a rule
allow two cubic feet of clear airspace and or any additional venting as
necessary to prevent the unit from overheating. All installation should
be tested for overall performance.

WARNING

!

!

CAUTION

!

!

®

This unit employs components that tend to produce arcs or sparks.

To prevent fire or explosion, do not install in compartments

containing batteries or flammable materials

To prevent fire, do not cover or obstruct ventilation openings.

Do not mount in zero-clearance compartment.

Overheating may result.

For continued protection against risk of fire, or electric shock

replace only with same type and ratings of fuse.

(LP gas).

Advertising