For your protection this heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system. Never operate heater if
ODS has been damaged or tampered with as this could expose you to Carbon Monoxide (a colorless, odorless gas) that
could result in injury or death. Early signs of Carbon Monoxide poisoning resemble influenza, with headaches, dizziness,
or nausea. If you develop these symptoms GET FRESH AIR AT ONCE. Turn off heater and call a qualified serviceman to
check heater. Some people are more affected by Carbon Monoxide than others: Including pregnant women, persons with
a heart or lung disease, anemia, those under the influence of alcohol, and those at high altitudes.

OPERATION

The Cozy thermostatically controlled units offer the additional benefit of automatically cycling the heating to maintain just
the right room temperature. VENTFREE GAS ROOM HEATERS ARE DESIGNED STRICTLY FOR “SUPPLEMENTAL”
ROOM HEAT USE AND SHOULD NEVER BE INSTALLED AS “SOLE SOURCE HEATING”.

ROOM HEATER SPECIFICATIONS

Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.

SAFETY INSTRUCTIONS

1)

Keep burner and control compartment clean.

2)

Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.

3)

Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns
or clothing ignition.

4)

Young children should be carefully supervised then they are in the same room with this heater.

5)

Do not place clothing or other flammable material on or near the heater.

6)

Any safety screen or guard removed for servicing must be replaced prior to operating the heater.

Page 3

MODEL NO./NAT.

BFT101

BFT201

BFT301

MODEL NO./L.P.

BFT102

BFT202

BFT302

Control

T-Stat Bulb

T-Stat Bulb

T-Stat Bulb

Height

22-1/2”

22-1/2”

22-1/2”

Width

14-9/16”

20-11/16”

26-13/16”

Depth

7”

7”

7”

Max. Input BTU hr.

10,000

20,000

30,000

Min. Input BTU Hr.

6,000

10,000

20,000

Gas Supply Line Size

1/2”

1/2”

1/2”

Optional Blower

No

Yes

Yes

Optional Floor Stand

Yes

Yes

Yes

Bathroom Installation

No

No

No

Bedroom Installation

Yes

No

No

Piezo Ignitor

Yes

Yes

Yes

Shipping Weight

22 Lbs.

32 Lbs.

35 Lbs.