c) If two modules inserted, but only power on one power module. The detect

circuit will judge the other module is abnormal (no output) then send

alarming signals.

2) REDUNDENT-MODE

In this mode two modules have to inserted and power on. Any one module

failed the other module will continue working and detect circuit send out the

alarming signals. Alarming singles can be removed by replacing a new power

module or user can disable it.

1.11 TROUBLE SHOOTING

If you have followed these instructions correctly, it should function normally.

Some common symptoms are, the system doesn’t work, buzzer alarms, shutdown

after running a very short period,…etc. If so, please check the following steps to verify

and correct it.

1) Check all connection (if pinouts is correct, if any connection loosed, if the direction

is incorrect,…etc.).

2) Check if any short-circuit or defective peripherals by plugging out the power

connector from each peripheral, one at a time. Shall the system functions again,

you have solved the problem.

3) Once you hear the buzzer sound or see the warning LED in RED, please check,

a) If the loading is under the minimum or over the maximum load of each

channel.

b) If the power source is well connected and supplied.

Shall the above condition is happened, please disconnect the power source and

wait for 2-3 minutes to release the protection status; then test it again.

c) If buzzer keeps alarming or LED indicates the power module failure, please

locate which power module is defective. Perform hot-swap procedures (ref. to

Sec. 1.8 Hot-Swap Procedures). Return the defective power module back to

your vendor for RMA procedure.

d) If you can not fix the problem, please contact your vendor for supporting.