INPUT CHARACTERISTICS:

MRM-6600P

l

VOLTAGE: 90 ~ 264 VAC FULL RANGE

l

FREQUENCY : 47 ~ 63 Hz

l

INPUT CURRENT: 10 / 5 A FOR 115 / 230 VAC

l

INRUSH CURRENT: 80A / 150A MAX. FOR 115 / 230 VAC PER POWER MODULE

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN.[A]

MAX.[A] PEAK

LOAD

LINE

5V

1.0

28

+5% - 4%

± 1%

50mV

12V

2.0

45

+5% - 4%

± 1%

120mV

-5V

0

0.8

+5% - 8%

± 1%

120mV

-12V

0

1.0

+5% - 5%

± 1%

120mV

3.3V

1.0

28

+5% - 3%

± 1%

50mV

+5VSB

0.1

3.5

± 5%

± 1%

50mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

REMARKS: TOTAL CURRENT OF +5V & +3.3V NOT EXCEED 45A, TOTAL MAXIMUM OUTPUT
OF 5V, 3.3V AND 12V: 572W

.

TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 80

0

C

l

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE

l

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE

INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE

l

EFFICIENCY: 68% TYPICAL, AT FULL LOAD

l

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

l

OVER POWER PROTECTION: 110 ~ 150% MAX.
OVER VOLTAGE PROTECTION:
+5V

à 5.7V ~ 6.5V, 3.3V à 3.9V ~ 4.5V, 12V à 13.3V~ 14.5V

OVER CURRENT PROTECTION:100~150%

l

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

l

SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

l

REMOTE ON / OFF CONTROL

l

FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL

l

HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION

l

BALANCE LOAD SHARING DESIGN

l

REMOTE SENSING DESIGN

l

ISOLATION: BUILT-IN IN THE POWER MODULE

l

MEET EN61000-3-2 CLASS D ( ACTIVE PFC )

l

DIMENSION: 84(H) X 150(W) X 254 (D) mm

l

COOLING:TWO 40 mm DC FANS (MODULE)

l

AC INLET IN EACH MODULE