1.8 INSTALLATION & TESTING

Turn off (Remote off) the on/off switch. Mount the power supply in the system

chassis using the proper mounting hardware, the mounting holes in the power

supply should match with those in the case. Attach the connectors to the M/B by

following the M/B instructions, there are various connectors / pin-outs of both

power supply and M/B. They should match each other; otherwise the

connection will cause undetectable harms.

Attach all the remaining power supply connections to the various peripherals as

needed. These connectors are “keyed”, so there will be only one possible way to

connect them.

Before applying power to the system, make sure there are no loose or incorrect

connections. You do not need to worry about the setting of AC Input voltage

because of the units’ full range features.

Double check that all pin-outs & connections to the M/B are matched properly.

Maybe you would like to test the redundancy function before you put back the

cover of your system chassis. Turn on (Remote on) the on/off switch, you will

notice if the power unit operates properly, individual LEDs and external

warning LED (please refer to Sec. 1.11 for detail explanation) are lit Green.

Then, when you remove one of the power modules, the warning buzzer in the

power system will sound and the external warning LED which displays the

status of the total power supply system will change color to be Red.