1.6 SPECIFICATION

NPUT CHARACTERISTICS:

R2Z-6350/400P

l

VOLTAGE: 90 ~ 264 VAC FULL RANGE

l

FREQUENCY : 47 ~ 63 Hz

l

INPUT CURRENT: 8.0 / 5.0 A FOR 115 / 230 VAC

l

INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN.[A] MAX.[A] PEAK(A)

LOAD

LINE

5V

3.0

25

± 5%

± 1%

50mV

12V

2

28

± 6%

± 1%

100mV

-5V

0.1

0.5

± 10%

± 1%

150mV

-12V

0.1

0.8

± 7%

± 1%

100mV

3.3V

1.0

20

± 5%

± 1%

50mV

+5VSB

0.1

2.0

± 5%

± 1%

50mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. [P-P]

REMARKS: TOTAL POWER OF +5V AND + 3.3V NOT EXCEED 175W

TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 384 W

.

TEMPERATURE RANGE : OPERATING 0

0

C --- 40

0

C, STORAGE –20

0

C --- 70

0

C

l

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE

l

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE

INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE

l

EFFICIENCY: 65% TYPICAL, AT FULL LOAD

l

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

l

OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V

à 5.7V ~ 6.7V, 3.3V à 3.7 ~ 4.7V, 12V à 13.0V ~ 15.0V

. SHORT CIRCUIT PROTECTION : SHUT DOWN

l

EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

l

SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950

l

REMOTE ON / OFF CONTROL

l

FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL

l

HOT-SWAPPABLE / HOT-PLUGGABLE 1 + 1 REDUNDANCY FUNCTION

l

BALANCE LOAD SHARING DESIGN

l

REMOTE SENSING DESIGN

l

ISOLATION: BUILT-IN IN THE POWER MODULE

l

MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )

l

DIMENSION: 84(H) X 101(W) X 265(D) mm ;

l

COOLING : TWO 38 mm DC FANS IN EACH MODULE