Zippy RHI-6460P User Manual

Page 14

Advertising
background image

1.6 INSTALLATION & TESTING

1. Please bear in mind never plug in AC outlet at first place.
2. Installation of power supply into the chassis by using mounting hardware, care should be taken
that all mounting holes of power supply should be matched up with those inside the chassis.
3. Connect the output wires into the right connecting position (identified as CN3, CN4, CN5..) of
the control board.
4. Attach the 6-pin (for AT system), 20-pin or 24-pin connectors (for ATX system) with correct pin
assignments into different motherboards, following the motherboard instructions. They should
all to be matched each other, otherwise unpredictable damage could be happened.
5. Attach the remaining power supply connectors to various peripherals in needed off. These are
important to keep good connections with outside world.
6. Please attach to the CN16 aerial connector, should be any ATX REMOTE ON function
available.

Soft Power Function:
Perhaps you would like to test the redundancy function before covering in your system chassis.
Be sure to Short the CN16 (PIN 1), AND (PIN2) terminals at first, Please refer to fig. 9. for
Further details.

You will notice that all LED , external warning LEDs are light in GREEN1 color, if the
power unit is operating properly. Warning Buzzer in a power supply system will sound
if any one of the power cord is removed,. the individual LED ( on the rear side or on the
front of control panel) indicating the power supply's status will not light neither, and the
power system will continue to backup the power output without any effecting normal
operation of the computer system.

Users can reset the Warning Buzzer by pressing a buzzer reset switch at the rear side or
the front control panel in the system chassis while the Buzzer continues warning. Refer to
some drawing on Sec. 1.3. The reset switch can also be opereated by connection wires
provided with the power supply system (Please refer to Sec. 1.9).


After plug in the power cord disconnected for power supply system testing purpose
before, now the Warning Buzzer silenced, external warning LED turn on GREEN again. You can
begin to test another power supply by performing the same procedure mentioned above.

If you want to use the power defective signa for certain purpose, there is a two pins connector ( refer
to the drawing in Sec. 1.3 and table in Sec. 1.9 ). It should be connected to the PMC card (for
NOVELL system) or faulty alert board (FAB-5, for Windows NT) properly.
Please refer to the PMC or FAB-5 User's Manual for details.

Turn off power supplies and main on / off switch, put on the cover of chassis and
tighten all screws retained before. Now, you have already completed the installation
of a RHX redundant power supply system.