Operating instructions (continued) – Campbell Hausfeld IN715601AV User Manual

Page 5

Advertising
background image

5

SN328K00

www.chpower.com

opEraTiNG iNSTrUCTioNS

(Continued)

rECoMMENDED HooKUp
The illustration below shows the
recommended hookup for the tool .
1 . The air compressor

must be able to
maintain a minimum
of 60 psi when the
tool is being used . An inadequate air
supply can cause a loss of power and
inconsistent driving .

2 . An oiler can be

used to provide oil
circulation through
the tool . A filter can
be used to remove liquid and solid
impurities which can rust or “gum
up” internal parts of the tool .

3 . Always use air supply hoses with

a minimum working pressure
rating equal to or greater than the
pressure from the power source if a
regulator fails, or 150 psi, whichever
is greater . Use 3/8 inch air hose for
runs up to 50 feet . Use 1/2 inch air
hoses for 50 feet run or longer . For
better performance, install a 3/8 inch
quick plug (1/4 inch NPT threads)
with an inside diameter of .315 inch
(8mm) on the tool and a 3/8 inch
quick coupler on the air hose .

4 . Use a pressure regulator on the

compressor, with an operating
pressure of 0 - 125 psi . A pressure
regulator is required to control
the operating pressure of the tool
between 60 and 100 psi .

opEraTioNal MoDE

Always know the

operational mode of

the tool before using. Failure to know
the operational mode could result in
death or serious personal injury.

SiNGlE SEqUENTial MoDE
This mode requires
the trigger to be
pulled each time a
fastener is driven .
The tool can be actuated by depressing
the Work Contact Element (WCE)
against the work surface followed by
pulling the trigger .
The trigger must be released to reset
the tool before another fastener can be
driven .

opEraTiNG a SEqUENTial Trip
Tool

Check the operation

of the Work Contact

Element (WCE) trip mechanism before
each use. The WCE must move freely
without binding through its entire
travel distance. The WCE spring must
return the WCE to its fully extended
position after being depressed. Do
not operate the tool if the WCE trip
mechanism is not operating properly.
Personal injury may occur.

1 . Disconnect the air

supply from the tool .

2 . Remove all fasteners

from the magazine
(see Loading/
Unloading) .

3 . Make sure the trigger

and work contact
element (WCE) move
freely up and down
without sticking or binding .

4 . Reconnect air

supply to the
tool .

5 . Depress the Work

Contact Element
(WCE) against the
work surface without
pulling the trigger . The tool MUST
NoT opEraTE
. Do not use the tool

if it operates without pulling the
trigger . Personal injury may result .

6 . Remove the tool from

the work surface .
The Work Contact
Element (WCE) must
return to its original down position .
The tool MUST NoT opEraTE .
Do not use the tool if it operates
while lifted from the work surface .
Personal injury may result .

7 . Pull the trigger

and depress the
work contact
element (WCE)
against the work surface . The tool
MUST NoT opEraTE .

8 . Depress the

Work Contact
Element (WCE)
against the
work surface . Pull the trigger . The
tool MUST opEraTE .

An improperly

functioning tool

must not be used. Do not actuate the
tool unless the tool is placed firmly
against the work piece.

loaDiNG/UNloaDiNG THE Tool
1 . Always disconnect the tool from

the air supply before loading
fasteners .

2 . Push down on the

latch button . Pull
back on the magazine
cover .

3 . Load a clip of fasteners with the

crowns straddling the magazine rail .

4 . Push the magazine

cover forward until
latch button pops up .

5 . Always unload all

fasteners before removing tool from
service . Unloading is the reverse of
loading, except always disconnect
the air supply before unloading .

latch
button

Magazine rail

60 psi

Min.
100 psi

Max.

150 psi or greater

3/8 inch I .D .

Movement

Advertising
This manual is related to the following products: