Specifications, Ppc-hdd(ms)a user's guide, Function specifications – Contec PPC-HDD(MS)A User Manual

Page 3: General specifications, 3 ppc-hdd(ms)a

Advertising
background image

PPC-HDD(MS)A User's Guide

Specifications

Function Specifications

Item Specification

Capacity 40GB

*1

Bus interface

IDE

Internal drive

2.5-inch hard disk drive

Transfer rate (Max.)

66.6MB/sec (Ultra DMA Mode 4), 16.6MB/sec (PIO Mode 4)

Reliability 1/10

13

bits read

Connection to PC CPU Module Dedicated 40-pin cable bundled
Extension

40-pin half-pitch connector for connecting slave IDE device
Capable of connecting one IDE device with master/slave selector switch

Access indicator *2

Front-panel LED (red)

High-temperature detection

Ambient temperature detected:47[+/-]3ºC or higher
Warning method: High-temperature detection function of bus interface driver software

External dimensions (mm)

27.4 (W) x 130.0 (D) x 98.0 (H) (Excluding protrusions)

Power consumption

+5VDC 0.88A (Max.)

Weight

300g (450g with optional unit fixing brackets attached)

Average life *3

5 years or 20,000 hours of energized time, whichever reached first

*1 1GB = 1,000,000,000bytes
*2 When two disk units (hard disk and/or silicon disk units) are connected in a master/slave arrangement, they have

common access indication. When either of the master and slave devices is accessed, therefore, both of their access

lamps come on at the same time.

*3 Under the assumptions : Less than 333 power on hours per month. And Seeking/Writing/Reading operation is less

than 20% of power on hours.

General Specifications

Item Specification

Operating ambient temperature

5 - 50ºC (at a temperature change rate of 20ºC/h or less)

Storage ambient temperature

-25 - 65ºC

Operating ambient humidity

8 - 90% RH (No condensation)

Storage ambient humidity

5 - 95% RH (No condensation)

Maximum wet-bulb temperature

29ºC

Vibration resistance
(during operation)

Tested 10 times (for 45 minutes) in each of the X, Y, and Z directions in
conformance with JIS C0040.
10 - 55 Hz: 0.035 mm
<With the optional hard disk unit fixing brackets attached>
Tested 10 times (for 80 minutes) in each of the X, Y, and Z directions in
conformance with JIS C0040.
10 - 57 Hz: 0.075 mm
57 - 150 Hz: 9.8 m/s

2

Shock resistance (during operation)

Tested 3 times in each of the X, Y, and Z directions in conformance with JIS

C0041. 49 m/s

2

, 11 ms

Operating ambiance

No corrosive gas

Operating altitude

2000 m or less *3

Installation location

Inside the control panel
(Do not install the base unit on the DIN rail when the hard disk unit is used.)

Over voltage category *1

II or lower

Pollution degree *2

2 or less

*1 The overvoltage category of a device indicates which distributor in the range from public distribution network to

machinery the device is assumed to be connected to. Category II applies to devices to which power is supplied from

fixed facilities. The surge voltage of those devices is 2500 V whose rated voltage is 300 V.

3

PPC-HDD(MS)A

Advertising