SA-430-17 Installation and Operating Instructions

CP5010B

03/31/10

OPTION SWITCHES

An 8-position DIP switch on the remote amplifier may be changed to select various options.

SW-1 Two-Tone - Turn this switch on to replace Phaser tone with Two-Tone.

SW-2 Mechanical Override - Pressing the Siren push-button normally produces Horn tone

while the rotary function switch is in Mechanical. Turn this switch on to manually override

Mechanical tone instead.


SW-3 SW-4

Siren push-button and Auxiliary Input Function

with Rotary Selector Switch in Standby

OFF

OFF (Default) Produces Horn tone while pressed.

ON

OFF Manual control of Mechanical tone.

Also Mechanical tone continues to fall when Rotary

Selector Switch is changed from Mechanical position.

OFF

ON

Manual control of Wail tone.

ON

ON

Activates Horn Ring Cycler 2 (HRC2) function.


SW-6 and SW-7 Cutout Input Polarity - The cutout input is normally disabled. Set the

activation polarity as follows:

Positive Activation - SW-6 and SW-7 OFF.

Negative Activation - SW-6 and SW-7 ON.

Disabled - SW-6 ON and SW-7 OFF.

SW-5 and SW-8 - Not Used… Leave Off.


Horn Ring Cycler 2 (HRC2) - Turn on DIP SW-3 and SW-4 to enable this feature. Also

connect the auxiliary input to the horn ring or other switch. While the siren is in standby, tap the

horn ring to bring the unit out of standby into Mechanical tone. Repeatedly tapping the horn

ring will cycle through Mechanical, Wail, Yelp, and Phaser tones. Tapping the horn ring twice

quickly will stop the siren tones and return the unit to standby. Pressing and holding the horn

ring will produce Horn tone until released. Then the siren will return to its previous siren tone or

standby.