TTW1 Universal Service

Replacement Blower

MITW -12 / -15 Series

Page 19

Step 17.

Secure the junction box cover, P/N
239-47199-00, to the junction box.

Step 18.

With the blower and transformer assembly
fastened to the water heater, the
remaining ends of the blower wire harness
can now be attached with the cord sets to
the blower and then the white connector
to the receptacle in the jacket head.

Step 19.

Find the rubber vent adapter kit, P/N
239-46263-00, provided with the blower
kit. Install the 2” vent adapter on the
exhaust side of the universal blower.
Discard the vent terminal included with
the vent adapter kit.

Tighten (2) screws on junction

box to secure cover.

Plug cord sets into

receptacles in blower.

Plug white connector into

receptacle in jacket head.

Be sure that vent pipe is

properly seated in the top

side of vent adapter.

Adequately tighten both

clamps on the vent adapter.

Rubber vent adapter

Note: In order to prevent condensate from draining

back into the blower (vertical or horizontal runs),
an optional condensate kit is available as a
service part (Condensate kit, P/N 239-45875-00).