Bradford White PDX2-75T6FSX User Manual

Page 19

Advertising
background image

19

Venting continued-

TABLE 4

3” (7.6 cm) PVC VENT CONNECTOR LENGTHS FROM INSIDE WALL

FOR LOW GROUND CLEARANCE INSTALLATIONS

Terminating #

of

Elbows

(intake + exhaust)

Maximum # of Feet

of Straight Pipe

(intake + exhaust)

(2) 90

 Elbows with (1) 90 Elbow

2 50

ft

(15.2 m)

(2) 90

 Elbows with (1) 90 Elbow

3 45

ft

(13.7 m)

(2) 90

 Elbows with (1) 90 Elbow

4 40

ft

(12.2 m)

(2) 90

 Elbows with (1) 90 Elbow

5 35

ft

(10.7 m)

(2) 90

 Elbows with (1) 90 Elbow

6 30

ft

(9.1 m)

(2) 90

 Elbows with (1) 90 Elbow

7

25 ft (7.6 m)

(2) 90

 Elbows with (1) 90 Elbow

8

20 ft (6.1 m)

TABLE 5

4” (10.1 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR

LOW GROUND CLEARANCE INSTALLATIONS

Terminating (Reduce 4” to 3”)

(Reduce 10.1 cm to 7.6 cm)

#of Elbows

(intake + exhaust)

Maximum # of Feet

of Straight Pipe

(intake + exhaust)

(2) 90

 Elbows with (1) 90 Elbow

2 120

ft

(36.6 m)

(2) 90

 Elbows with (1) 90 Elbow

3 115

ft

(35.1 m)

(2) 90

 Elbows with (1) 90 Elbow

4 110

ft

(33.5 m)

(2) 90

 Elbows with (1) 90 Elbow

5 105

ft

(32.0 m)

(2) 90

 Elbows with (1) 90 Elbow

6 100

ft

(30.5 m)

(2) 90

 Elbows with (1) 90 Elbow

7

95 ft (29.0 m)

(2) 90

 Elbows with (1) 90 Elbow

8

90 ft (27.5 m)

Advertising
This manual is related to the following products: