1C. Heater Identification

Consult the rating plate on the boiler. The following

example simplifies the heater identification:

SECTION 2.

Boiler Assembly and Placement

2A. Field Assembly

These boilers are available in two configurations; the

JVH has a hot surface ignition pilot and integral draft

fan, and the JVS has an electronic intermittent ignition

device (I.I.D.). Look for the model designation on the

rating plate, which can be found on top of the boiler in

the right rear corner.

The Bradford White automatic vent dampers are

standard on all JVS models. The Bradford White

side wall power venters can be used on JVS models.

Special instructions for their installation are included

in the vent damper and power venter package. Read

them carefully before installation.

JVS

1

st

thru

3

rd

C

haraCters

(M

odel

d

esignation

)

BJV = B

radford

W

hite

C

orp

. M

odel

JV

B

rute

M

ini

4

th

C

haraCter

(i

gnition

s

ysteM

)

s = s

park

i

gnition

h = h

ot

s

urfaCe

p

ilot

5

th

thru

7

th

C

haraCters

(s

ize

)

i

nput

MBtu / h

8

th

C

haraCter

(

fuel

)

n = n

atural

g

as

p = p

ropane

g

as

9

th

C

haraCter

(f

iring

s

ysteM

)

D =

on

/

off

10

th

C

haraCter

(C

onstruCtion

o

ption

)

i = (s

tandard

)

J = p

uMp

(050-125

only

)

11

th

C

haraCter

(a

ltitude

in

f

eet

)

s = (0 - 2,000) n

atural

or

(0 - 5,000) p

ropane

h = (2,001 - 5,000) n

atural

i = (5,001 - 8,000) n

atural

and

p

ropane

J = (8,001 - 10,000 n

atural

and

p

ropane

12

th

C

haraCter

(C

ountry

)

u = usa & C

anada

13

th

C

haraCter

(r

eVision

)

2 = s

eCond

r

eVision

JVH

1

st

thru

3

rd

C

haraCters

(M

odel

d

esignation

)

BJV = B

radford

W

hite

C

orp

. M

odel

JV

B

rute

M

ini

4

th

C

haraCter

(i

gnition

s

ysteM

)

s = s

park

i

gnition

h = h

ot

s

urfaCe

p

ilot

5

th

thru

7

th

C

haraCters

(s

ize

)

i

nput

MBtu / h

8

th

C

haraCter

(

fuel

)

n = n

atural

g

as

p = p

ropane

g

as

9

th

C

haraCter

(f

iring

s

ysteM

)

C =

on

/

off

10

th

C

haraCter

(C

onstruCtion

o

ption

)

s = s

tandard

11

th

C

haraCter

(a

ltitude

in

f

eet

)

s = (0 - 2,000) n

atural

or

(0 - 5,000) p

ropane

h = (2,001 - 5,000) n

atural

i = (5,001 - 8,000) n

atural

and

p

ropane

J = (8,001 - 10,000 n

atural

and

p

ropane

12

th

C

haraCter

(C

ountry

)

u = usa & C

anada

13

th

C

haraCter

(r

eVision

)

2 = s

eCond

r

eVision

MODEL

J V

IGNIT

SYST

S
H

SIZE

0 5 0
0 7 5
1 0 0
1 2 5
1 6 0
2 2 5

FUEL

N

P

FIRING

SYST

C
D

CONST

OPTION

S
P

I

J

ALTITUDE

S
H

I

J

REVISION

2

BRADFORD

WHITE

COUNTRY

U

V

J

U

2

B

Table 1. Boiler Model Identification.

1

2

4

5

6

7

8

9

10

11

12

13

3

Advertising
This manual is related to the following products: