WARNING

High voltage exposure. Use caution to avoid

personal injury during this procedure.

Double Element, Non-Simultaneous, Three Phase

Operation.

Water In Tank Is Cold With Power ON.
1. This procedure assumes line voltage, ECO and

elements are in working order.

2. Turn power “ON” to water heater.
3. Set multi-meter to “Volts AC”
4. Check across terminals L4 and T2 of

upper thermostat (see illustration 41).

A) Rated voltage NOT present,

Recheck upper ECO. If ECO is okay,

replace thermostat.

B) Rated voltage IS present,

proceed to next step.

5. Check across element terminals

(see illustration 42).

A) Rated voltage NOT present,

check wire connections from

thermostat to element.

B) Rated voltage IS present,

Repeat element testing

see page 15.

Illustration 41

Illustration 42

Tank Does Not Deliver Enough Hot Water.
1. This procedure assumes line voltage, ECO and elements are in

working order.

2. Turn power “ON” to water heater and set multi-meter to “Volts AC”
3. Adjust temperature setting of upper & lower thermostat to the

Highest setting. Water temperature in tank must be below thermostat

setting for this test.

4. See illustration 41 above. Check voltage across terminals L4 & T2 of

upper thermostat.

A) Rated voltage IS present, okay, upper thermostat is calling

for heat. Go to step 5 below.

B) Rated voltage NOT present, replace upper thermostat.

5. Adjust temperature setting of upper thermostat to the minimum

setting. Water temperature in tank must be above thermostat setting

for this test.

6. Check voltage across terminals L3 & T4 of upper

thermostat (see illustration 43).

A) Rated voltage NOT present, replace upper thermostat.
B) Rated voltage IS present, upper thermostat is okay. Go to

step 7 on next page.

Illustration 43

Page 29

SERVICE PROCEDURE RE-IV

Light Duty Commercial

Thermostat Testing

29