Unable to adjust hot water temperature

1) Is the water temperature thermistor operating normally ?

2) Is the change over solenoid (SV1) normal ?

a.

# Disconnect the connector B5, and measure the
resistance between the white wires, see below
for resistance readings.

Thermistor resistance valves:

59 ºF

= 11.4 ~ 14 K Ω

86 ºF

= 6.4 ~ 7.8 K Ω

113 ºF

= 3.6 ~ 4.5 K Ω

140 ºF

= 2.2 ~ 2.7 K Ω

221 ºF

= 0.6 ~ 0.8 K Ω

Normal: Proceed to check item 2 below.
Faulty: Replace the water temperature
thermistor.
(Service Procedure IGE-6, page 48)

a.

# Disconnect the changeover solenoid (SV1)
connector, and measure resistance at the
solenoid terminals.
Normal: 1.7 ~ 2.1 K Ω

If normal, proceed to b.
Faulty: Replace the gas valve.
(Service Procedure IGE-9, page 50)

b.

Measure the voltage at the changeover solenoid
(SV1) yellow ~ black wires.

Normal: 80 ~ 100 VDC

If normal, proceed to check item 3, on next
page.
Faulty: Replace the PCB unit.
(Service Procedure IGE-2, page 47)

VI - TROUBLESHOOTING

(cont.)

BEFORE CARRYING OUT CHECKS MARKED WITH A # SIGN, DISCONNECT THE POWER SUPPLY.