The Logic is designed to allow for a 7 volt loss in the field wiring. By increasing
the wire size you decrease the voltage loss. The rule is the bigger the wire, the
smaller the voltage loss. Use only solid copper wire manufactured for Direct
Bury Applications. To calculate the voltage drop, use the charts on pages 18 and
19. For a maximum of one valve only operating simultaneously, the following
chart applies.

Total Length of

Valves Operating Wire Size

Each 2 Wire Run Simultaneously Gauge MM

2

Feet

Meters

0-2,500

0-762

1 Valve

#14 2.5

2,500-5,000

762-1,525

1 Valve

#12 4

5,000-7,500

1,525-2,286

1 Valve

#10 6


Calculating Voltage Drop and Proper Wire Sizing
Figure the wire distance from the controller to the farthest valve. Find that
distance by adding the distances on the chart and subsequent voltage drops.
Add these voltage drops to figure the total voltage drop at that wire size. Should
the voltage drop exceed 7.0 volts, the next larger sized wire should be calculated
until the voltage drop is equal to or less than 7.0 volts. For multiple valves
operating simultaneously, you must calculate and add the loss at each valve.
See example 1 and 2 below.

Example 1

Chart 1

Logic to V1 (Valve 1)
1000´

Logic 1
To Valve

14 Ga
Table

Voltage drop
from Chart

Controller
to V1

1000´@1
valve

1.290 V.D.

Total Voltage Drop 1.290 O.K. use 14 Ga
24 Volts less 1.290 = 22.71 Volts

CALENDAR ODD / EVEN

PRE WET / FERTIGATION

MASTER CLEAR

PROGRAM RECEIVER

FERTIGATION ON

MASTER ON

.35 amps inrush charts

Voltage Loss

.25 amps holding chart

Voltage Loss

Length 1 Valve 2 Valves 3 Valves 4 Valves Length 1 Valve 2 Valves 3 Valves 4 Valves

Wire Size 14

2.58 R factor

Wire Size 14

2.58 R factor

100 0.181

0.361

0.542

0.722

100

0.129

0.258

0.387

0.516

200 0.361

0.722

1.084

1.445

200

0.258

0.516

0.774

1.032

300 0.542

1.084

1.625

2.167

300

0.387

0.774

1.161

1.548

400 0.722

1.445

2.167

2.890

400

0.516

1.032

1.548

2.064

500 0.903

1.806

2.709

3.612

500

0.645

1.290

1.935

2.580

600 1.084

2.167

3.251

4.334

600

0.774

1.548

2.322

3.096

700 1.264

2.528

3.793

5.057

700

0.903

1.806

2.709

3.612

800 1.445

2.890

4.334

5.779

800

1.032

2.064

3.096

4.128

900 1.625

3.251

4.876

6.502

900

1.161

2.322

3.483

4.644

1000

1.806

3.612

5.418

7.224

1000

1.290

2.580

3.870

5.160






Advertising