CAPACITOR START COMPRESSORS
Follow Split Phase procedure except for the two YELLOW lead con-
nections. These leads are connected to the starting capacitor as
shown-above. The capacitor can be any value and voltage equal to or
greater than the original supplied with the compressor. A 200 MFD
220V capacitor will start most of the compressors in use.

ACCESSORIES
Model 2605 Test Lead Kit provides Four (4) 30 in. heavy duty test
leads with colored insulated clips on each end, a 6 ft. power cord with
male plug on one end and insulated clips on the other, and a 220V
adaptor cord with a female receptacle on one end and insulated clips
on the other.

LIMITED WARRANTY
All products sold are warranted against defects in workmanship or
materials under normal use for one year. Manufacturer assumes no
liability on the actual use of this equipment. Safety responsibility lies
with the user.

In return for shipping the merchandise PREPAID to factory service
location, Thermal Engineering Company will make a good faith effort
for prompt disposition regarding any product which proves to be de-
fective whether in or out of warranty. A complete description of the
problem should be included. If product is damaged in transit to you,
file a claim with the carrier.

For repair return to your local distributor or Thermal Engineering.

INSTRUCTIONS

FOR MODEL

2601 QUIK-START

HERMETIC

COMPRESSOR

STARTER

Model 2601 Quik-Start will start all single phase compressors up to
5HP—110, 220, or 277 VAC. Read these instructions carefully
before using the Quik-Start.

This device is intended for use only by qualified air conditioning
and refrigeration service technicians. Use extreme caution when
using this unit. Make sure the system being tested is disconnected
from power before connecting the Quik-Start. Do not use fuses
rated higher than 30A. Read the safety precautions carefully before
using.

Before using the Quik-Start, check the compressor for grounded
windings. Connect an ohmmeter from the COMMON terminal to
the compressor case. If the ohmmeter shows any reading less than
infinity (open), the compressor is defective and the Quik-Start
should not be used.
Compressor amperage draw can be measured by placing a clamp-on
ammeter around the WHITE Quik-Start lead.

Revised 02/

05/

07

Thermal Engineering Company

A division of Airserco Manufacturing Company

7555 Tyler Blvd.—Unit 1

Mentor, OH 44060

USA

www.thermalengineeringcompany.com

Thermal Engineering Company

A division of Airserco Manufacturing Company

7555 Tyler Blvd.—Unit 1

Mentor, OH 44060

USA

www.thermalengineeringcompany.com

COMPRESSOR

START

RUN

COMMON

Starting
Capacitor

Fuse

Start

Off

QUIK- START

POWER

WHITE

YELLOW

YELLOW

BLACK

RED

R
U
N

GREEN

CHASSIS GROUND

Advertising