Nexen BSB07 965040 User Manual

Page 11

Advertising
background image

11

FORM NO. L-21225-F-0813

TROUBLESHOOTING

Problem

Probable Cause

Solution

Failure to engage (brake)

Weak or broken springs

Replace broken springs

Failure to disengage (1)

Control valve malfunction -

air not getting to brake

Check for low air pressure or replace the
control valve.

NOTE: The Unit has been designed to
release before (at or below) 5.5 bar [80
psi] Required disengagement pressure
higher than 5.5 bar [80 psi] may indicate
improper assembly.

Failure to disengage (2)

Air is leaking around the O-ring seals.

Replace the O-rings.

Loss of torque

Fraction Facing is worn or dirty.

Replace friction face.

Advertising
This manual is related to the following products: