Nexen RPS16G-C0070T/360-EP2U 966554 User Manual

Page 11

Advertising
background image

11

FORM NO. L-21252-B-1209

Table 3

Pinion Bushing Bolt Information

Model

Bolt Type

Tightening Torque

RPG16

M4

3.5 Nm [30.98 in-lb]

RPG20

M5

7.0 Nm [61.96 in-lb]

RPG25

M6

12.0 Nm [106.21 in-lb]

RPG32

M6

12.0 Nm [106.21 in-lb]

RPG40

M6

12.0 Nm [106.21 in-lb]

RPG4014

M8

38.0 Nm [336.26 in-lb]

Flange Mount Pinion Installation (ISO 9409)

1. Clean the gearhead mounting face and pilot bore,

inspecting for contaminates, burs, or surface defects
that would interfere with full contact between the
pinion and flange.

2. Using a test indicator, check the rotational flatness of

the face as shown in Figure 12. Position the contact
point of the indicator where the pinion will contact
it. Rotate slowly for a minimum of one complete
revolution and note the total amount of variance.

Pinion Side

Gearhead Side

Figure 14

3. Position the contact point of the indicator at bottom

dead center of the pilot bore as shown in Figure 13.
Rotate slowly for a minimum of one complete turn and
note the amount of total variance in one rotation.

10. Once the fasteners are fully torqued verify the pinion

is centered on the gear. If not, measure the positional
error and then remove the pinion as described in the
Disengaging The Roller Pinion section on page 16.
Repeat the pinion installation procedure and offset the
pinion by the recorded error plus the previous off set
value. When the pinion is fully torqued and properly
centered then verify pinion concentric variation at the
center of the pinion rollers as shown in Figure 15.
Variation on this surface must be less than ± 0.030
mm [±0.0010 in].

4. If either of the following conditions are true, the

gearhead itself may contribute to excessive pinion
preload variation, a reduction in pinion life and/or
accuracy. The user should consider having the
gearhead re-worked or replaced.


a. The measured total variance of the mounting face is

greater than 0.013 mm [0.0005 in].

b. The measured total variance of the pilot bore wall is

greater than 0.005 mm [0.0002 in].

Note: In some cases an adapter will be required to mount

the pinion on the reducer. If so, proceed with Step
5, if not, skip to Step 13.

5. Clean the adapter flange and pilot where it will contact

the gearhead flange inspecting for contaminates,
burs, or surface defects that would interfere with full
contact between the adapter and gearhead flange.
See Figure 14.

6. Apply a serviceable thread locking compound to the

adapter mounting screws then assemble the adapter
to the gearhead, leaving the mounting screws snug but
do not tighten at this time as shown in Figure 15.

7. Position a test indicator at bottom dead center of

the pilot bore wall as shown in Figure 15 and zero
the indicator. Rotate the assembly slowly by using
the gearhead input shaft a minimum of one complete
revolution while noting the amount of total indicator
variance and mark the angular location in which the
lowest reading occurs throughout the rotation.

.

Figure 12

Figure 13

CAUTION

Preload must be applied before putting your
system into operation. Refer to APPLYING
PRELOAD to properly set preload for your
RPG system.