Assembly – Ryobi TS1143L User Manual

Page 18

Advertising
background image

18

ASSEMBLY

SQUARING THE BLADE TO THE MITER TABLE

See Figures 19 - 23.

Unplug the saw.

Pull the saw arm all the way down and engage the lock

pin to hold the saw arm in transport position.

Unlock the miter lock lever.

Rotate the miter table until the pointer aligns with zero

detent on the miter scale.

Lock the miter lock.

Loosen bevel lock knob and set saw arm at 0

°

bevel (blade

set 90

°

to miter table). Tighten bevel lock knob at stop.

Place a square against the miter table and the flat part

of saw blade.

NOTE: Make sure that the square contacts the flat part

of the saw blade, not the blade teeth.

Rotate the blade by hand and check the blade-to-table

alignment at several points.

The edge of the square and the saw blade should be

parallel as shown in figure 21.

If the top or bottom of the saw blade angles away from

the square as shown in figures 22 and 23, adjustments
are needed.

Loosen the bevel lock knob.

Adjust positive stop adjustment screw to bring saw blade

into alignment with the square. See

Positive Stop Adjust-

ment in the Adjustments section.

Retighten bevel lock knob. Recheck blade-to-table align-

ment.

NOTE: The above procedure can be used to check blade
squareness of the saw blade to the miter table at both 0

°

and 45

°

angles.

The saw has two scale indicators, one on the bevel scale
and one on the miter scale. After squaring adjustments have
been made, it may be necessary to loosen the indicator
screws and reset them to zero. See figure 20.

Fig. 22

Fig. 23

VIEW OF BLADE NOT SQUARE WITH MITER

TABLE, ADJUSTMENTS ARE REQUIRED

VIEW OF BLADE NOT SQUARE WITH MITER TABLE,

ADJUSTMENTS ARE REQUIRED

MITER

TABLE

COMBINATION

SQUARE

BLADE

BEVEL

LOCK KNOB

Advertising